Home›Blog›Cell Therapy Chain of Identity and Custody: A Handoff Map
Advanced TherapiesPublished: November 26, 2026Last updated: November 26, 2026

Cell Therapy Chain of Identity and Custody: A Handoff Map

How the ISBT 128 CoI Identifier joins a patient's identifiers, where custody changes hands before infusion, and what a platform must enforce.

AG
Ankur GahlotHead of Projects and Analytics, Zelthy
Share:
Chain of Identity & Custody hero: a cryogenic dry shipper with data logger linked by a scan beam to a labeled cell therapy bag
TL;DR
  • An autologous cell therapy changes hands about a dozen times between apheresis and infusion, and identity breaks where systems fail to join their identifiers.
  • ICCBBA's ST-028 defines a 15-character ISBT 128 CoI Identifier, allocated before or at first collection, that links every donation for one patient's therapy.
  • A courier's live map is not a chain of custody: each transfer needs a time-stamped event tied to the CoI Identifier, with temperature and seal condition.
  • Labeling was the top deviation category for licensed 351 HCT/P manufacturers in FY2022 to FY2024 (FDA CBER): print on demand, reconcile, scan to proceed.
  • FDA expects chain of identity to be described in the IND and validated for licensure; FACT-JACIE recommends the CoI Identifier but does not require it.

An autologous cell therapy changes hands about a dozen times between the patient's arm at apheresis and the same patient's infusion, and each handoff is a chance to lose the link between the cells and the person they belong to. The Standards Coordinating Body, which works on standards for regenerative medicine, states the risk plainly: different tracking systems and formats produce records that do not line up, and "such errors create a risk of administering the wrong product to a patient". FDA reviewers expect the controls to be designed in early. At a 2024 CBER webinar, Kimberly Schultz, director of FDA's Division of Gene Therapy 2, said "maintenance of the chain of identity should be described in the IND and validated for licensure".

This post is part of Zelthy's vein-to-vein guide to cell therapy orchestration, which introduces chain of identity (COI) and chain of custody (COC). Zelthy, an AI-native platform-as-a-service built on the open-source Zango framework, lets cell and gene therapy sponsors configure chain-of-custody event capture, identifier mapping and treatment-center workflows as applications they own, with audit trails and HIPAA and GDPR controls. This post covers how the ISBT 128 Chain of Identity Identifier works, where custody changes hands, what couriers and loggers give you, why labels remain the weak point, and what a platform should enforce.

Chain of identity and chain of custody: the working definitions

The field now has shared definitions. ICCBBA's ISBT 128 standard ST-028, using wording developed with the Standards Coordinating Body, defines chain of custody as "concurrent, permanent, auditable documentation illustrating the guardianship of a cell or gene therapy product from its origin through its final disposition", and chain of identity as the permanent and transparent association of a therapy's unique identifiers from procurement of cells "throughout the full product(s) lifecycle including post treatment monitoring".

Note "concurrent": custody is recorded when it changes, not reconstructed afterwards. And the identity link must survive into long-term follow-up, not stop at the infusion bag.

One patient, four identifiers: how the ISBT 128 CoI Identifier fits

The practical problem is not a missing identifier but too many. One autologous patient can carry a medical record number, an ISBT 128 Donation Identification Number (DIN) on the apheresis bag, a manufacturer's patient or batch number and a courier waybill. Each system is consistent on its own; identity breaks in the translation between them.

ST-028 was written to give every party one shared key. According to ICCBBA's ST-028, version 1.1.0 (June 2025):

  • Structure: the CoI Identifier is 15 characters: the fixed string "CH", the issuing organization's five-character Facility Identification Number (FIN), a two-digit year and a six-digit sequence number. Once assigned, it is never reassigned.
  • Timing: it should be allocated before, or at the time of, collection of the first donation.
  • Relationship to the DIN: it does not replace each collection's DIN; it is the same on every donation linked to one patient's therapy.
  • Manual entry: eye-readable versions carry a boxed checksum so a typed identifier can be validated.

The IG-050 implementation guide adds that the identifier can link collections and doses in one-to-many and many-to-one patterns, can be issued by the sponsor, manufacturer or collection facility, and should be allocated under a written agreement between them. In electronic messages it travels as the XML element ChainOfIdentityIdentifier.

Under the US HCT/P tracking rule, a distinct identification code created for tracking may not include the donor's name, Social Security number or medical record number. Yet the YESCARTA prescribing information (revised June 2026) tells sites to match the patient's identity to the cassette and infusion bag on receipt, before preparation and before infusion, and not to infuse if they do not match. So identity has two layers: an anonymous code systems join on, and human-readable identifiers people check at the bedside.

IdentifierIssued byWhere it lives
Medical record numberTreatment centerEHR, wristband (never in tracking codes)
ISBT 128 DINCollection facilityApheresis bag label
ISBT 128 CoI IdentifierSponsor, manufacturer or collection facility, by agreementCollection label, portals, messages: the key the others join to
Manufacturer patient or batch IDManufacturerMES, batch record, product label
Courier waybill and shipper serialCourierCourier system, data logger
MRN wristband, DIN-labeled bag, courier waybill and shipper joined by threads to one purple ISBT 128 CoI Identifier key
Identity rarely breaks because an identifier is missing. It breaks when systems fail to join the ones they have.

Adoption is uneven, so systems will map between schemes for years. The third-edition FACT-JACIE Immune Effector Cell standards recommend assigning an ISBT 128 CoI Identifier (C7.3.2, D7.3.2) but do not require it.

The handoff map: where custody changes from apheresis to infusion

Count the handoffs first, because each needs an identity check, a custody record or both. Below is Zelthy's illustrative mapping of a fresh autologous collection flown both ways to a US treatment center; ground-only routes drop the four airline transfers. A 2024 peer-reviewed analysis of the CAR-T supply chain makes the same point: "the chain of custody requirement increases logistics complexity by adding extra check points and steps".

#Custody transferIdentity checkRecord the platform should hold
1Patient to apheresis unitDonor identity verifiedCollection event, DIN, CoI Identifier
2Apheresis unit to site cell labBag label scannedLabel print and reconciliation
3Site to courierShipper serial tied to CoI IdentifierSigned handover, logger start
4 to 5Courier to airline and backSeal intactCourier feed events
6Courier to manufacturerLabel and paperwork verifiedReceipt, temperature history
7Manufacturer to courierProduct label vs CoI IdentifierRelease link, handover
8 to 9Courier to airline and backSeal intactCourier feed events
10Courier to site cell labCassette and bag matched on receiptReceipt, storage location
11Cell lab to infusion unitMatched before preparationThaw time, operator
12Nurse to patientMatched at bedsideAdministration record
Cell therapy handoff map: a path of custody tiles from Collect to Infuse, with checks at handoffs and one coral custody gap
Every tile is a custody event. The question is whether the record is written at the tile or reconstructed later.

Seven of the twelve transfers in this map require someone to compare identifiers, and three of those happen inside the treatment center after the product returns. That is where the site's own workflow, not the manufacturer's portal, decides whether the check is a scan or a glance.

Courier handoffs and data loggers: where "real-time" breaks

Couriers own the longest unobserved stretches of the chain, and their records do not always fit yours. A Consortium for Pediatric Cellular Immunotherapy report found that "few shipping companies have a designated COC form designed to meet this new standard", that some couriers "will use only their proprietary tracking systems", and that one site found mid-shipment it needed "special software and a micro-USB adapter" to read the temperature logger.

Shipper hardware has improved. Condition monitors on cryogenic shippers now record far more than temperature: Cryoport's SmartPak II, for example, logs location, internal and external temperature, orientation, pressure, humidity and shock, and uses light as a measure of "security breaches, compromised packaging or premature openings." But a live dot on a courier's map is not a chain of custody. "Real-time" should mean:

  • Events, not dashboards: each tender and delivery arrives as a time-stamped custody event tied to the CoI Identifier, not a PDF after delivery.
  • Condition with custody: temperature, tilt and seal status travel with the event.
  • Exceptions that route: a broken seal or silent logger opens a case with an owner and a timer. Predicting excursions is covered in our post on AI temperature excursion detection for cell and gene therapy.

Labels and label reconciliation: still the weak point

In FDA's biological product deviation report summaries, labeling was the largest category for licensed 351 HCT/P manufacturers in each of the last three fiscal years: 20 of 25 reports (80%) in FY2022, 6 of 18 (33%) in FY2023 and 5 of 17 (29%) in FY2024. For licensed gene therapy product manufacturers, labeling accounted for 1 of 18 reports (6%) in FY2022, none of 18 (0%) in FY2023 and 3 of 17 (18%) in FY2024 (FDA CBER, FY2024 annual summary). The counts are small and reflect only what firms detect and report.

Bar chart: labeling share of FDA deviation reports, 351 HCT/P 80%, 33%, 29% vs gene therapy 6%, 0%, 18% in FY2022 to FY2024
Labeling was the top deviation category for licensed 351 HCT/P manufacturers in every year from FY2022 to FY2024. Source: FDA CBER.

The cost is not theoretical. A wrong label on a patient-specific product can put the wrong cells into a patient, and for an autologous therapy there is usually no second product to fall back on.

Three controls matter:

  • Print on demand, from verified data. Print each label from the verified record at the moment it is needed, not from pre-printed stock, so the label carries exactly the identifiers the system holds. Where people type an identifier, use the ST-028 checksum to validate it.
  • Reconcile every label. US drug GMP requires procedures to reconcile the quantities of labeling issued, used and returned; for patient-specific products, do it per patient and print event.
  • Scan to proceed. A label check that the system records but does not enforce is a note, not a control.

What regulators and standards expect

No single rule covers chain of identity end to end; which provisions apply depends on how and where a product is regulated.

SourceWhat it expects for COI and COC
FDA CAR-T guidance (2024)Chain of identity [described in the IND and validated for licensure](https://www.fda.gov/media/178014/download), per CBER's March 2024 webinar.
21 CFR 1271.290Bidirectional donor-to-consignee tracking with a distinct code ([eCFR via Cornell LII](https://www.law.cornell.edu/cfr/text/21/1271.290)).
21 CFR Part 11For in-scope records: [secure, computer-generated, time-stamped audit trails](https://www.law.cornell.edu/cfr/text/21/11.10), sequence checks and authority checks.
FACT-JACIE IEC standards, 3rd editionWritten COI and COC procedures; donor identity verified before collection; CoI Identifier recommended ([FACT summary of changes, October 2025](https://www.factglobal.org/media/2qhj13x2/sts-res-5-026_summary-of-changes-3rd-ed-fact-jacie-standards-for-iecs_r1-28oct2025.pdf)). In effect since [2 February 2026](https://www.isctglobal.org/telegrafthub/blogs/francheska-juliano/2026/03/06/jacie-launches-dedicated-iec-certification-pathway).
EudraLex Volume 4, Part IV (EU GMP for ATMPs)Bidirectional tracking from donation to recipient; linked codes kept at least 30 years after expiry and quickly accessible after an adverse reaction; autologous mix-up prevention; batch release confirms the starting material matches the recipient ([sections 6.35 to 6.39, 9.19, 11.27](https://health.ec.europa.eu/document/download/ad33d9dd-03f0-4bef-af53-21308ce2187d_en)).

Recent changes raise the stakes. FDA's June 2025 removal of the REMS for autologous CAR-T eased site certification, opening the door to more treatment centers and more handoffs. FDA's May 2026 final guidance on CMC flexibilities does not address chain of identity, so identity controls are unchanged. For Part 11 scoping, see Zelthy's guide to Part 11 for patient support program systems.

What a chain of custody orchestration platform should enforce

Verify identity at the moment of transfer, not afterwards. The standard definition already demands it: chain of custody is "concurrent, permanent, auditable documentation", written when custody changes, not reconstructed afterwards. A platform should:

  • Hold an identifier map joining the CoI Identifier, DINs, manufacturer IDs and courier serials, and reject records that cannot be joined.
  • Write one custody event per handoff (who, when, where, condition), captured by scan.
  • Enforce sequence: no infusion record without a matching bedside scan.
  • Keep an audit trail and a one-click export of one patient's full chain.
  • Route exceptions to named owners with timers.
  • Reduce site burden. The ASTCT 80/20 Task Force warned that the number of manufacturer IT platforms "will eventually overwhelm clinical site staff" and recommended universal labels and single sign-on.

Several commercial platforms address these needs. TrakCel's OCELLOS tracks chain of custody and chain of identity at each stage. Title21 Health Solutions says its Smart-CGT software "verifies chain of identity and custody at every handoff". ERP and logistics vendors offer their own layers. Test any option against the handoff map above.

Zelthy takes the platform route. Sponsors configure the identifier map, custody events, scan-gated steps and audit trails as their own application on Zelthy, and integrate courier, MES and treatment-center systems through APIs and FHIR. The Zelthy Advanced Therapies page outlines the use cases. For the serialized supply chain side, see the pharmaceutical traceability landscape.

Can every handoff be scan-gated?

On Zelthy, sponsors configure the identifier map, custody events, scan-gated steps and audit trails as their own application, and connect courier, MES and treatment-center systems through APIs and FHIR.

See the Advanced Therapies solution →

Proof point: traceability and scale on Zelthy

No cell therapy COI outcome metric for a Zelthy deployment is approved for publication, so we do not claim one. The closest evidence is traceability work: India's first controlled distribution network for a pharma product was implemented on Zelthy, and a blockchain-powered supply chain platform built on Zelthy reduced stockouts by 15% and improved inventory turnover by 25%. Across programs, Zelthy supports more than 1 million patients in 12+ countries, with 300+ applications deployed. These are supply chain and platform results, not cell therapy outcomes.

Frequently asked questions

What is chain of identity in cell therapy?

Chain of identity is the permanent link between a patient or donor, the cells collected from them and every product made from those cells, kept from collection through infusion and long-term follow-up. It is maintained by assigning shared identifiers and verifying them, by scan or by trained staff, at each handoff.

What is the ISBT 128 Chain of Identity Identifier?

It is a 15-character code defined in ICCBBA standard ST-028: the letters CH, a five-character Facility Identification Number, a two-digit year and a six-digit sequence number. It is assigned before or at the first collection, sits alongside each donation's DIN, and links all collections and doses for one patient's therapy.

Who assigns the CoI Identifier: the sponsor, manufacturer or collection site?

Any of them can, if it is licensed with ICCBBA. The implementation guide says the parties should agree, for example in a pharmacy manual, site training document or contract, who allocates the identifier and when, so that the collection site has it before cells are collected.

How many handoffs are there between apheresis and infusion?

It depends on the route. In Zelthy's illustrative mapping of a fresh autologous collection shipped by air both ways, there are 12 custody transfers, seven of which include an identity check. Ground-only shipping removes the four airline transfers, and on-site cryopreservation adds a step.

Do courier tracking systems satisfy chain of custody requirements?

Not on their own. Courier systems record where a shipment is, but chain of custody needs a signed, time-stamped record of each transfer tied to the patient's identifier, together with the temperature and seal condition. The orchestration platform should take courier events through an integration and attach them to the patient's custody record.

Next step

Mapping chain of identity and custody for a cell therapy program? Talk to the Zelthy team about configuring custody events, identifier mapping and audit trails on a platform you own.

Sources

  1. ICCBBA, ISBT 128 Standard: Chain of Identity (CoI) Identifier, ST-028 v1.1.0 (June 2025)
  2. ICCBBA, Implementation Guide: Using the ISBT 128 Chain of Identity (CoI) Identifier, IG-050 v1.0.0 (December 2023)
  3. Standards Coordinating Body, Project: Chain of Custody/Chain of Identity
  4. FDA CBER, Guidance Webinar: Considerations for the Development of CAR T Cell Products (7 March 2024)
  5. 21 CFR 1271.290, 21 CFR 11.10 and 21 CFR 211.125 (Cornell LII)
  6. FDA, YESCARTA Prescribing Information (revised June 2026)
  7. FDA CBER, Biological Product and HCT/P Deviation Reports, Annual Summary FY2024
  8. FACT, Summary of Changes, Third Edition FACT-JACIE International Standards for Immune Effector Cells (27 October 2025)
  9. Rinala T (EBMT), JACIE launches dedicated IEC certification pathway, ISCT Telegraft (6 March 2026)
  10. European Commission, EudraLex Volume 4, Guidelines on GMP specific to ATMPs (2017)
  11. Lindgren C, et al. Processing laboratory considerations for multi-center cellular therapy clinical trials. Cytotherapy (2021)
  12. Cryoport, SmartPak II Condition Monitoring System fact sheet (2023)
  13. Nikiforow S, et al. ASTCT 80/20 Task Force consensus. Transplantation and Cellular Therapy (2023)
  14. Holland SM, et al. A quest for stakeholder synchronization in the CAR T-cell therapy supply chain. Frontiers in Bioengineering and Biotechnology (2024)
  15. Title21 Health Solutions, Smart-CGT product page
  16. Cencora, AmerisourceBergen and TrakCel launch integrated platform (25 January 2022)
  17. FDA, FDA eliminates REMS for autologous CAR T cell immunotherapies (26 June 2025)
  18. AABB, FDA issues final guidance on CMC flexibility for cell and gene therapy BLAs (6 May 2026)

This article is for general information and is not legal or regulatory advice. Confirm product-specific requirements with your regulatory and quality teams.

Related Solution

Mapping chain of identity and custody for a cell therapy program?

Zelthy is pharma's advanced therapies platform: cell and gene therapy sponsors configure chain-of-custody event capture, identifier mapping and treatment-center workflows as applications they own, with audit trails and HIPAA and GDPR controls. Zelthy supports more than 1 million patients in 12+ countries, with 300+ applications deployed.

See the Advanced Therapies Solution →

Similar Blogs