A dry shipper stays deeply cold until its nitrogen is nearly spent, so a thermometer alarm often fires only hours before the product is at risk.
Tilt, delay, ambient heat and a worn shipper use up hold time faster than planned; tracking nitrogen use warns earlier than a temperature threshold.
Zelthy found no peer-reviewed validation of AI that predicts excursions in cell therapy dry shippers; measure lead time and false alerts on your own lanes.
Guidance requires excursions to be monitored, recorded and investigated; manufacturer QA (the QP in the EU), not the courier or a model, decides on the product.
A cell and gene therapy temperature excursion is rarely a sudden event. In a liquid nitrogen dry shipper the product chamber stays deeply cold until the nitrogen charge is nearly spent, so a thermometer alarm often fires only hours before the product is at risk. An autologous CAR-T is made from the patient's own cells, so a lost shipment cannot be replaced from stock. The useful question is not only whether a shipment is in range now, but when it is likely to leave that range.
This article goes deeper on one layer of Zelthy's cell therapy orchestration guide: detecting and responding to excursions in transit. Zelthy is an AI-native platform-as-a-service for life sciences, built on the open-source Zango framework, on which manufacturers configure cold chain tracking, chain-of-custody event capture and excursion alert workflows as applications they own, alongside their courier's monitoring. Below: the temperature regimes, why dry shippers fail, what AI cold chain monitoring can and cannot predict, how to keep false alarms down, what regulators expect after an excursion, and who decides what happens to the product.
Cell and gene therapy temperature regimes in 2026
A temperature excursion is any exposure outside the range prescribed for storage or transport (WHO TRS 961, Annex 9). For cell and gene therapies, that range is set product by product on the label, and the labels differ more than many logistics plans assume.
Product type (example)
Shipping condition
Rule at the site
Main detection risk
Autologous CAR-T (Yescarta)
LN2 dry shipper at ≤ -150°C
Store at ≤ -120°C; one-time storage at -80°C (±10°C) for up to 90 days, never back to colder storage
Nitrogen depletion from tilt or delay; late temperature signal
AAV gene therapy shipped frozen (Zolgensma)
Frozen at ≤ -60°C
Refrigerate at 2 to 8°C on receipt; use within 14 days; do not refreeze
Receipt timing; a refreeze is irreversible
AAV gene therapy shipped cold (Hemgenix)
2 to 8°C
Refrigerate; protect from light; do not freeze
Freezing in transit; light exposure
Two consequences follow. First, an excursion limit is not one number per shipment: the same CAR-T bag has a -150°C shipping condition and a -120°C storage limit, and a one-time -80°C allowance that, once used, cannot be reversed. Your alert logic has to know which state the bag is in. Second, the regimes are shifting. Labels are already moving (Yescarta's one-time -80°C allowance), and researchers are examining whether some cell therapies could skip cryopreservation in transit altogether: a 2025 review sets out the case for ambient cell transport. Each new regime brings different failure modes.
Why temperature is a late signal in a dry shipper
A dry shipper holds liquid nitrogen in an absorbent lining, and the product sits in the cold vapour. Each shipper is validated for a hold time below -150°C, and the margin between that hold time and the actual journey is what keeps cells below the -120°C storage limit. Plan a hold-time margin your quality team has justified for the lane, not just the scheduled transit time. While nitrogen remains, the chamber reading barely moves; the risk is in how fast the charge is being used up.
Four things use it up faster than planned:
Tilt and tipping. A dry shipper is designed to travel upright, and orientation is one of the variables researchers test when measuring its thermal performance: Spijkers et al. ran an instrumented shipper upright, at 45° and at 90°. An orientation sensor on the logger is what tells you a carrier has laid a shipper on its side.
Ambient heat. A 2025 study of an instrumented dry shipper found a constant evaporation rate that depends on ambient conditions, and built a model that estimates the remaining nitrogen indirectly (Spijkers et al., International Journal of Refrigeration).
Shipper condition. A worn lining, a damaged neck seal or a dented shell reduces hold time, so shippers need checking between uses. Weight is a useful check: Spijkers et al. found a shipper's mass falls at a steady rate as the nitrogen evaporates, so weight tracks the nitrogen left.
Illustrative scenario, not measured data: the forecast moves on day 2; the thermometer moves on day 5.
Consider an illustrative case. A shipper with a 10-day validated hold time is tipped on day 2, and customs then pushes arrival from day 3 to day 6. A model that tracks nitrogen use from tilt and ambient data moves the forecast exhaustion from day 10 to day 5 as soon as the tilt is reported, and flags a shortfall as soon as the delay is known on day 3. A plain -150°C threshold alarm fires at about day 5.3, roughly 7 hours before the product reaches -120°C, while the box is still in customs. The difference is not accuracy. It is how much time people have to act.
What AI cold chain monitoring can detect, and the evidence so far
Real-time loggers on cryogenic shippers report more than temperature. Cryoport's SmartPak II, for example, records location, internal and external temperature, pressure, orientation, light, humidity and shock, with light used as a sign of premature opening. Marken and Controlant describe similar real-time telemetry backed by 24/7 monitoring teams. The AI layer sits on top of these streams. It is worth separating what each method does from what has been shown.
Method
Signals used
What it catches
Published evidence
Hold-time forecasting
Charge weight, tilt, ambient temperature, elapsed time
Nitrogen running out before delivery
Physics basis published (constant evaporation, ambient-driven model); no peer-reviewed CGT validation found
Delay and lane risk scoring
Flight status, customs events, lane history, weather
Shipments that will outlast their margin
Vendor claims only; no peer-reviewed validation found
Payload temperature forecasting
Ambient profile, packaging type
Passive packaging drifting out of range
MIT study: good fit in sample, [contradictory results under new ambient conditions](https://ctl.mit.edu/publications/supply-chain-modeling-temperature-sensitive-pharmaceutical-goods); quantile regression held up
Sensor anomaly detection
Multi-sensor streams
Faulty or drifting sensors versus real events
Improved isolation forest on 3 refrigerated trucks over one week: [precision 0.88, recall 0.87, AUC 0.91](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0315322)
The honest summary: the physics supports forecasting, and anomaly detection works on modest datasets, but we found no published, peer-reviewed validation of an AI model that predicts excursions in cell therapy dry shippers. Ask any vendor for lead time gained, missed events and false alerts on your own lanes, not a headline accuracy figure.
A quieter use is assembling the record. A 2024 MIT thesis with Johnson & Johnson found that tracing a gene therapy's temperature history across supply chain legs still "has to be done through manual review of disparate temperature records". Joining logger data from each leg to the batch and patient record is unglamorous work that speeds up every investigation.
Tier the alerts. A forecast shortfall goes to the courier control tower first; a confirmed shortfall or a breach of the label limit goes to manufacturer QA at the same time.
Tie each alert to an action. If nobody can recharge, re-route or expedite, the alert is information, not an alarm.
Know the blind spots. Real-time loggers can go quiet, for example out of network coverage or when transmission is restricted in flight, and a reading prevents nothing unless someone acts on it.
Measure the model. Track lead time, missed events and the share of alerts that led to action, by lane.
Who sees the excursion alert first?
On Zelthy, manufacturers bring courier telemetry into the same record as the patient schedule, custody events and the QA deviation, and route excursion alerts by role with timers and escalation.
Guidance sets expectations for monitoring and investigation, not for the technology. None of the texts below requires real-time devices; they require that transport conditions are defined, monitored and recorded, and that excursions are investigated.
EU GDP (2013/C 343/01), section 9.2: an excursion should be reported to the distributor and recipient, and "a procedure should also be in place for investigating and handling temperature excursions".
WHO TRS 961 Annex 9: transport monitoring devices calibrated, and alarms checked at their set points, at least once a year.
USP <1079> series: a risk-based approach to storage and distribution. The mean kinetic temperature chapter, <1079.2>, covers evaluating excursions during storage and transportation of drug products; it is not a shortcut for cryopreserved cells.
The response playbook: who is paged and who decides
Stage
Who is paged
Typical actions
Forecast shortfall
Courier control tower; manufacturer logistics
Expedite, re-route, arrange recharge, or transfer to a pre-charged backup shipper
Limit breached in transit
Manufacturer QA; treatment center coordinator
Keep the product cold, notify distributor and recipient, open a deviation, put the patient schedule on hold
On receipt
Site cell therapy lab; manufacturer QA
Quarantine, download the full record, match identity, do not infuse until QA decides
Disposition
QA (QP in the EU), with medical input
Release, reject and remanufacture, or supply as out-of-specification with the treating physician's informed agreement
The courier acts on the shipment; manufacturer QA decides on the product.
Three points deserve attention. A transfer to a backup shipper saves the cells but is itself a change of custody, so it must be captured as a custody event; Zelthy's guide to chain of identity and custody for cell therapy covers that handoff. Second, the evidence base for disposition is product-specific: a 2026 ATCC study found excursion impact "differed markedly by model", with some cell lines losing more than half their viability after 2 hours at -20°C and another losing about 2%. Third, rejecting an autologous product can mean no treatment. EU ATMP GMP allows an out-of-specification product to be given for imperative clinical reasons, with the manufacturer's risk evaluation and the physician's recorded agreement; in the US, sponsors run expanded access programs for out-of-specification CAR-T, a route explained in Zelthy's guide to expanded access programs.
Whatever the model predicts, a person in QA makes the disposition decision, and the record must show what the model said, who saw it and when. That is a computerized-system question as much as a logistics one; see Zelthy's posts on Part 11 audit trails and monitoring AI outputs in regulated workflows.
Where Zelthy fits
Zelthy does not ship or monitor product. Couriers and logger providers do that. Manufacturers use Zelthy's Advanced Therapies and traceability building blocks, including temperature data capture, to bring courier telemetry into the same record as the patient schedule, chain-of-custody events and the QA deviation, and to route excursion alerts by role with timers and escalation. Across clients such as Roche, BMS and AstraZeneca, programs built on Zelthy serve more than 1 million patients in 12+ countries. For the wider architecture, see the implementation guide to complete traceability.
Frequently asked questions
What is a temperature excursion in cell and gene therapy logistics?
It is any exposure of the product to temperatures outside the range on its label for storage or transport. For a cryopreserved CAR-T this can mean warming above the shipping limit (for example -150°C); for an AAV gene therapy shipped at 2 to 8°C it can mean freezing.
How long does a liquid nitrogen dry shipper hold temperature?
Most dry shippers keep below -150°C for 5 to 10 days under normal conditions, and planners commonly add at least a 30% margin. Tilting, delays, heat and a worn shipper all shorten the real hold time.
Can AI predict a temperature excursion before it happens?
It can forecast likely shortfalls by tracking nitrogen use, tilt, delays and lane history, which gives hours or days of warning that a temperature threshold cannot. We found no peer-reviewed validation for cell therapy dry shippers yet, so measure lead time and false alerts on your own lanes.
Who decides whether an excursion-affected cell therapy can be used?
The manufacturer's quality unit (the Qualified Person in the EU) decides, using the full temperature record, product data and medical input. Couriers and AI tools inform that decision but do not make it.
Is real-time monitoring required by GDP?
No. EU GDP and WHO guidance require that transport conditions are monitored, recorded and investigated when breached, but they do not specify real-time devices. Real-time data matters because it gives people time to act before the product is lost.
Next step
Want excursion alerts, custody events and QA disposition in one record you own? Talk to Zelthy.
Sources
Kite / FDA, Yescarta prescribing information (2026)
AABB News, FDA approves expanded storage options for Kite CAR T-cell products (June 2026)
Novartis / FDA, Zolgensma prescribing information (revised June 2026)
CSL Behring / FDA, Hemgenix prescribing information (revised April 2026)
Cryoport, SmartPak II Condition Monitoring System fact sheet
Spijkers et al., Assessment of the thermal performance of a dry-shipper, International Journal of Refrigeration (2025)
Holland SM, et al. A quest for stakeholder synchronization in the CAR T-cell therapy supply chain. Frontiers in Bioengineering and Biotechnology (2024)
Gostage J, et al. From cold chain to ambient: benefits, risks, and evidence across cell therapy logistics. Mol Ther Methods Clin Dev (2025)
Gweder and Guadarrama, MIT CTL, Supply chain modeling for temperature-sensitive pharmaceutical goods (2022)
Xie et al., An anomaly detection scheme for data stream in cold chain logistics, PLOS ONE (2025)
Lee J., MIT thesis with Johnson & Johnson, temperature management for gene therapies (2024)
European Commission, Guidelines on Good Distribution Practice, 2013/C 343/01
WHO Technical Report Series 961, Annex 9 (2011)
USP General Chapter <1079.2>, USP-NF (2023)
21 CFR 1271.260, 1271.265 and 211.192
FDA warning letter 320-26-124 (September 2026)
European Commission, Guidelines on GMP for Advanced Therapy Medicinal Products (2017)
Kite expanded access program for out-of-specification brexucabtagene autoleucel
Mikhaylov J., ATCC, temperature excursions in cryopreserved cells, CRYO 2026
This article is for general information and is not legal or regulatory advice. Excursion limits and disposition rules are product-specific; follow the approved labeling and your quality system, and review with your regulatory and quality teams.
Related Solution
Managing excursions across cell and gene therapy shipments?
Zelthy is pharma's advanced therapies platform: temperature data capture, chain-of-custody events, role-based excursion alerts and the QA deviation in one record the manufacturer owns, working alongside your courier and logger providers. Programs built on Zelthy serve more than 1 million patients in 12+ countries, for clients such as Roche, BMS and AstraZeneca.